Error Code CI

Main board and compressor inverter board cannot communicate

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: CI LED blinks

What This Means

Communication cable disconnected; Connector pins bent or corroded; Main board PCB failure; Inverter board PCB failure

What actually causes this:

Loose cable or failed inverter board

First Thing to Check

Unplug and check if inverter cable is firmly connected

Parts Involved

Main PCBInverter PCBCommunication Cable

How to Fix

  1. 1

    1. Check communication cable between main and inverter boards

  2. 2

    2. Inspect connector pins for damage or corrosion

  3. 3

    3. Use oscilloscope to verify signal transmission

  4. 4

    4. Check PCB soldering quality on both boards

Need more help with your Samsung RF22R7351AA?