Error Code FF
Freezer fan motor is not running
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: FF LED blinks
What This Means
Fan motor wire disconnected; Motor bearing seized; PWM control signal lost; Motor winding failure
What actually causes this:
Fan motor burned out or connector loose
First Thing to Check
Unplug and check if freezer fan connector is fully connected
Parts Involved
How to Fix
- 1
1. Measure voltage at MAIN PCB CN20-16 to CN20-18
- 2
2. Voltage should be between 7V and 12V
- 3
3. Check fan motor connector seating
- 4
4. Listen for fan noise when powered