Error Code CLD
Compressor position sensor is not working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: CLD LED blinks
What This Means
Compressor connector loose; Resistance sensor (R2) circuit open; Inverter PCB soldering defect; Short circuit on PCB
What actually causes this:
Loose compressor wires or inverter board failure
First Thing to Check
Unplug and check if compressor connector is firmly seated
Parts Involved
How to Fix
- 1
1. Check compressor wire connections
- 2
2. Measure resistance of R2 component (should be 0.09 ohms)
- 3
3. Check inverter PCB soldering quality
- 4
4. Inspect for short circuits on PCB traces
Other Error Codes for RF22R7351EF
Freezer temperature sensor is broken or disconnected
Outside temperature sensor is not working
Ice storage room temperature sensor is not working
Flex Zone damper heater circuit is broken
Refrigerator temperature sensor is broken or disconnected
Flex-Zone temperature sensor is broken or disconnected
Freezer fan motor is not running
Control board IO expander chip is not working