Error Code CP

Main board and display panel are not talking to each other

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: CP LED blinks

What This Means

Communication cable disconnected; Connector pins bent or corroded; Main board PCB failure; Display panel PCB failure

What actually causes this:

Loose cable or failed circuit board

First Thing to Check

Unplug and check if communication cable between boards is firmly seated

Parts Involved

Main PCBDisplay Panel PCBCommunication Cable

How to Fix

  1. 1

    1. Check communication cable between main and panel boards

  2. 2

    2. Inspect connector pins for damage or corrosion

  3. 3

    3. Use oscilloscope to verify signal transmission

  4. 4

    4. Check PCB soldering quality on both boards

Need more help with your Samsung RF22R7351EU?