Samsung RF23DB9900Refrigerator

Error Code 83C

The compressor motor rotor position sensor failed

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 83C

What This Means

Compressor motor wiring disconnected (U, V, W); Compressor phase voltage loss; IPM position sensing circuit failure; PCB soldering defect; Defective compressor

What actually causes this:

The compressor wires are loose or the inverter can't detect motor position

First Thing to Check

The compressor won't start at all

Parts Involved

CompressorInverter PBAMotor Wiring

How to Fix

  1. 1

    1. Check compressor wire connections (U, V, W terminals)

  2. 2

    2. Verify all wires are firmly connected

  3. 3

    3. Check PCB bottom side for cold solder joints

  4. 4

    4. Measure AC voltage at compressor terminals during startup

  5. 5

    5. If wiring and soldering normal, replace Inverter PBA

  6. 6

    6. If error persists, check compressor rotor position sensor

Need more help with your Samsung RF23DB9900?