Error Code COMM-INVERTER

Compressor controller not communicating with main board

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: LED blinks

What This Means

Inverter communication cable disconnected; Main PCB communication circuit failure; Inverter PCB failure; Compressor circuit malfunction

What actually causes this:

Loose inverter cable or PCB failure

First Thing to Check

Check cable between main board and inverter board

Parts Involved

Main PCBInverter PCBInverter Communication Cable

How to Fix

  1. 1

    1. Verify cable connection between Main and Inverter PCB

  2. 2

    2. Check connector pins for proper seating

  3. 3

    3. With oscilloscope, verify signal transmission

  4. 4

    4. If signals present, replace defective PCB

Need more help with your Samsung RF24R7201SA?