Error Code 29
Convertible zone defrost system secondary error
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 29
What This Means
Defrost heater connector disconnected; Defrost heater burned out or open circuit; Defrost heater shorted; Control module malfunction
What actually causes this:
Defrost heater element burned out
First Thing to Check
Check for ice buildup in convertible zone compartment
Parts Involved
How to Fix
- 1
1. Power off refrigerator and wait 5 minutes
- 2
2. Separate Main PCB CN70 connector from PCB
- 3
3. Measure resistance between CN70_1-7 and 1 — should be 63 ohms ± 7%
- 4
4. Check heater connector for corrosion or loose pins
- 5
5. If resistance is correct, replace Main PCB control module