Samsung RF29DB9750Refrigerator

Error Code 87C

The compressor inverter is overheating

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: 87C

What This Means

IPM FET temperature over 120°C; Excessive compressor current draw; Inverter cooling insufficient; Ambient temperature too high; Defective inverter thermal sensor; Defective IPM module

What actually causes this:

The compressor is working too hard or the inverter area has poor ventilation

First Thing to Check

Feel if the compressor area is hotter than normal

Parts Involved

Inverter PBAIPM ModuleCompressorCooling System

How to Fix

  1. 1

    1. Check FET temperature of PCB (Inverter part)

  2. 2

    2. Normal operating temperature should be below 120°C

  3. 3

    3. Check ambient temperature around compressor area

  4. 4

    4. Ensure adequate ventilation around compressor

  5. 5

    5. Allow compressor to cool before restart

  6. 6

    6. If error continues, replace Inverter PBA

  7. 7

    7. Check for short-circuit in compressor motor

Need more help with your Samsung RF29DB9750?