Error Code 11
Condenser cooling fan not functioning
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Left - ⑤ LED ON
What This Means
Fan motor not spinning; Feedback signal contact failure; Motor wire missing or disconnected; Motor bearing failure; FG signal loss
What actually causes this:
Dust clogs condenser fan blade path or motor connector vibrates loose
First Thing to Check
Verify 7-12V present at CN75 #1 and #2; check for fan motor hum
Parts Involved
How to Fix
- 1
Check voltage between MAIN PCB CN75 #1 (GRAY) and #2 (SKY BLUE)
- 2
Voltage should be 7V~12V DC
- 3
Verify FG signal generation during rotation
Other Error Codes for RS25J5008SP
Defrost heater temperature sensing not working
Damper heater not responding or circuit open
Compressor fails to operate or protection activated
Ice maker sensor malfunction or connection issue
Ice maker ejection or level detection malfunction
Freezer evaporator fan not operating properly
Refrigerator compartment temperature measurement failure
Freezer temperature sensor not responding