Error Code TC2
The temperature sensor for the drying heater is giving bad readings.
Moderate
Address soon - your appliance may not work properly
Also displayed as: TC2
What This Means
Dry temperature sensor fault; Condensing sensor fault; Faulty connections of the sensor connector; Main PCB fault; IPM temperature abnormally high
What actually causes this:
The drying temperature sensor has failed or its connector has come loose.
First Thing to Check
Unplug the washer for one minute and plug it back in.
Parts Involved
How to Fix
- 1
1. Check the connections for the dry heater temperature sensor connector
- 2
2. If the dry heater temperature sensor has a functional error, replace it
- 3
3. A TC2 check occurs when the dry/condensing sensor is faulty
Other Error Codes for WA47CG3500AVA4
The vibration sensor that helps keep the washer balanced is not working.
The vibration sensor board is not communicating properly.
The washer is not getting enough voltage from the electrical outlet.
The washer detected a problem with the water heating system.
The washer detected a problem with the water heating system.
The clutch sensor is sending the wrong signal to the control board.
The temperature sensor for the wash water is giving bad readings.