Error Code TC3
A temperature sensor related to moisture condensing is not working.
Moderate
Address soon - your appliance may not work properly
Also displayed as: TC3
What This Means
Faulty dry condensing sensor connections; Main PCB fault
What actually causes this:
The condensing sensor has a loose connection or has failed.
First Thing to Check
Unplug the washer for 60 seconds, then plug it back in and try again.
Parts Involved
How to Fix
- 1
1. Check all temperature sensor connections
- 2
2. Replace sensor or Main PBA if defective
Other Error Codes for WA50R5400AV
Your washer cannot detect how much water is in the tub.
A vibration sensor wire has come loose inside the washer.
The washer's WiFi module has lost its connection to the main board.
Your washer's door lock mechanism is not working correctly.
Your washer is filling with too much water and cannot detect when to stop.
Your washer has detected a water leak.
An internal power module in the washer is overheating.
Your washer's vibration sensor is not communicating properly.