Error Code TC2
The washer cannot read the drying temperature correctly.
Moderate
Address soon - your appliance may not work properly
Also displayed as: TC2
What This Means
Dry temperature sensor fault; Faulty and incorrect connections of the dry condensing sensor; Connector connected incorrectly or disconnected
What actually causes this:
The drying temperature sensor connector has come loose or the sensor has failed.
First Thing to Check
Unplug the washer for 60 seconds, then try a wash-only cycle without drying.
Parts Involved
How to Fix
- 1
1. Check the connections for the dry heater temperature sensor connector
- 2
2. If the dry heater temperature sensor has a functional check, replace it
Other Error Codes for WA54A7305AV
The washer's clutch moved but did not reach the correct position.
The washer's main computer chip has malfunctioned.
The washer's main computer chip has malfunctioned.
The washer's main computer chip has malfunctioned.
The drying heater has an electrical problem.
The washer has detected a water leak somewhere in the system.
The laundry load is uneven and the washer cannot spin safely.
The washer detected too many soap bubbles and is working to remove them.