Error Code NC2
The heat exchanger cover panel is not in place
Moderate
Address soon - your appliance may not work properly
Also displayed as: NC2
What This Means
Heat exchanger protective cover not inserted; Magnet of heat exchanger protective cover not detected; PBA defect
What actually causes this:
The protective cover was removed during cleaning and not reinstalled properly
First Thing to Check
Locate the heat exchanger cover at the bottom of the unit and make sure it is fully inserted
Parts Involved
How to Fix
- 1
1. Insert the heat exchanger protective cover and operate
- 2
2. Check if there is a magnet inside the heat exchanger protective cover
- 3
3. If the problem remains unresolved, it may be a PBA defect
Other Error Codes for WD53DBA900HZA1
A dryer button is being registered as stuck or continuously pressed
The heat pump compressor motor has failed or lost its connection
A temperature sensor on the refrigerant line is reading incorrectly
A temperature sensor on the evaporator inlet is reading incorrectly
A temperature sensor on the evaporator outlet is reading incorrectly
A temperature sensor on top of the compressor is reading incorrectly
The dryer heater temperature sensor is reading incorrectly
The door lock has been forced too many times and is malfunctioning