Error Code 8C2
The vibration sensor board has detected an error in its own readings
Moderate
Address soon - your appliance may not work properly
Also displayed as: 8C2
What This Means
MEMS PBA has a data error; Wire connections to MEMS PBA are loose or disconnected; MEMS PBA is defective
What actually causes this:
The vibration sensor board has a loose wire connection or has developed a fault
First Thing to Check
Unplug the washer for 2 minutes and plug it back in to see if the error clears
Parts Involved
How to Fix
- 1
1. Check the wire connections to the MEMS PBA
- 2
2. Verify connector is properly seated
- 3
3. Replace the MEMS PBA if necessary
Other Error Codes for WF56H9100AG
An internal electronic module cannot communicate with the main board
The motor speed controller cannot communicate with the main board
The washer's main computer chip has stopped working
The washer's main computer chip has stopped working
The washer cannot detect the water level properly
The washer motor cannot spin or is struggling to turn
The washer is not getting water to fill the tub
The incoming water is too hot for the selected cycle