Error Code CLg
The dryer's vent is blocked and air cannot flow through
Moderate
Address soon - your appliance may not work properly
Also displayed as: CLg
What This Means
Lint buildup in the vent duct; Vent duct too long or with too many bends; External vent hood blocked
What actually causes this:
Lint has built up inside the dryer vent hose or the vent exit outside your home is blocked
First Thing to Check
Clean the lint filter inside the dryer, then go outside and check that the vent exit flap opens freely
Parts Involved
How to Fix
- 1
1. Clean the lint filter
- 2
2. Check your vent condition — refer to the ducting requirements section
- 3
3. Inspect the external exhaust hood for blockages
- 4
4. Clean the entire exhaust duct system