Error Code PC

The water distribution motor that directs spray isn't working properly

Moderate

Address soon - your appliance may not work properly

Also displayed as: No display (PC in recall)

What This Means

Synchronous motor (distributor motor) is out of order; Location in the cam is incorrect; Micro switch is defective; Cam assembly is misaligned or damaged

What actually causes this:

The motor that directs water flow to different spray zones has failed or gotten stuck

First Thing to Check

Try running a normal cycle — if dishes on one side are consistently not clean, this motor may be the issue

Parts Involved

Distributor MotorMicro SwitchCam AssemblyMain PBA

How to Fix

  1. 1

    1. Check the connections for the distributor motor and micro switch connectors — reconnect

  2. 2

    2. Check whether the coil in distributor motor is conductive (remove connectors before measuring) — Normal: approximately 3.6-4.0k ohms

  3. 3

    3. Check micro switch position sensing: conduction between brown wire and violet wire — Micro switch ON: SHORT, Micro switch OFF: OPEN. Use n5 Service test mode. Sign should alternate ON/OFF; NG if stuck in one state for 120 seconds

  4. 4

    4. Adjust Cam Assembly and find the fault — replace Cam Assembly if faulty

  5. 5

    5. Check whether half load is operating normally — check operation voltage: Normal 110-120V. Check distributor motor relay voltage between CN401 pin 3 (Brown) and CN101 pin 1 (White) — Normal: 110-120V while operating

  6. 6

    6. Check the Power Relay

Need more help with your Samsung DW80M9550USAA?