Error Code HS
Humidity sensor failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: HS
How to Fix
- 1
Turn off dryer and call for service.
- 2
In diagnostic mode, press START/PAUSE once and check moisture sensor bar display.
- 3
With door closed and motor tumbling, place fingers across moisture sensor bars — display should show 30–255.
- 4
Disconnect NA6 connector from main PCB and measure resistance between NA6-(GN) pin and chassis ground — must be less than 1Ω.
- 5
Place a jumper between NA6-(OR) and NA6-(BL).
- 6
Measure resistance between the two moisture sensor bars in the lint filter housing — must be less than 1Ω.
- 7
If sensor bar resistance is greater than 1Ω: check all connections and wires between NA6 terminal and sensor bars.
- 8
Check sensor harness connectors for corrosion, loose or bent pins, and broken wires.
- 9
If all wiring checks pass but issue persists: replace main PCB.
Other Error Codes for DLEX3370V
EEPROM operation is abnormal
Outlet thermistor open or shorted (short circuit variant)
Outlet thermistor open or shorted
Sensors do not detect that steam generator is full within 60 seconds
Electric dryer power cord not connected correctly or house power supply is incorrect
Power failure / house fuse blown / circuit breaker tripped
NFC module is wrong / incompatible
Pump valve resistance less than 10 in test mode; pump circuit fault