Error Code E5
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
What This Means
DC water supply pump failed or disconnected; Harness wire to pump connector loose or disconnected
How to Fix
- 1
Activate diagnostic test mode and press START/PAUSE four times.
- 2
Wait for each test step to complete before advancing — rapid pressing can damage main board.
- 3
Read the AD value on the display.
- 4
If AD value is 10 or above: pump is normal.
- 5
If AD value is below 10 (E5 displayed): check harness connection between wiring harness and DC pump connector — reseat connectors.
- 6
If connector is secure and E5 persists: replace the DC water supply pump assembly.
Other Error Codes for DLEX5000V
Modem is abnormal. Displayed in test mode only.
Humidity sensor failure.
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.