Error Code HS
Humidity sensor failure.
Moderate
Address soon - your appliance may not work properly
Also displayed as: HS
What This Means
Moisture/electrode sensor failure; Harness connector loose
How to Fix
- 1
Turn off dryer and call for service
- 2
For technician: turn off power and discharge voltage before measuring
- 3
Remove NA6 connector from controller; short pin 3 (Orange Wire) and pin 2 (Blue Wire) together
- 4
Measure resistance in electrode load circuit with door closed; expect below 10 Ω when short is applied
- 5
If resistance is not below 10 Ω with short: check electrode load and harness connector; check harness-linking connector
- 6
Apply damp cloth to electrode sensors in drum; in diagnostic test verify IMC display value is 50–130 (2.5 V DC) at 70–40% moisture
- 7
Measure voltage between NA6 pin 3 (Orange) and pin 2 (Blue); should be 2.5 V DC for wet clothes, above 4.0 V DC for dry clothes
- 8
If sensor readings are out of range, check electrode sensor connector at front bulkhead and replace electrode sensor if damaged
- 9
If readings pass but HS persists, replace controller
Other Error Codes for DLEX5000V
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.