Error Code dE
Door switch abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Note: dE is only displayed during diagnostic test mode, not during normal operation.
- 2
Disconnect power before measuring resistance.
- 3
With door closed: measure resistance between BL2-connector (White wire) and BK2-connector (Black wire) after removing BL2 and WH4 connectors from controller; expect less than 2500 Ω.
- 4
If resistance is above 2500 Ω with door closed, check door switch continuity (COM to NO terminal should be less than 1 Ω).
- 5
With door open: measure resistance between BL2 (White wire) and BK2 (Black wire); expect 300–600 Ω (lamp resistance in circuit); if out of range, check lamp and door switch.
- 6
With door open: measure resistance between WH4 (Yellow wire) and BL2 (White wire); should be less than 1 Ω.
- 7
With door closed: measure resistance between WH4 (Yellow wire) and BL2 (White wire); should be less than 1 Ω.
- 8
If all wiring checks pass, check and replace controller.
- 9
Check harness-linking connector.
Other Error Codes for DLEX7600WE
EEPROM error
Thermistor of blower housing open or shorted
Thermistor of blower housing open or shorted (secondary)
FlowSense - ductwork 90-95% blocked
FlowSense - ductwork restriction detected (80% blocked)
Thermistor of steam generator open or shorted
Power failure or incorrect power supply
Pump (DC motor) failure