Error Code tE2
Thermistor of blower housing open or shorted (secondary)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Follow identical diagnostic steps as tE1.
- 2
Disconnect power and remove the NA6 connector from the controller.
- 3
Short Pin 4 (Blue Wire) and Pin 3 (Orange Wire) of the NA6 connector with a metal jumper.
- 4
If error clears, check connector seating at NA6 and 6-pin controller connector.
- 5
If error persists, separate the thermistor harness from the thermistor assembly connector and measure resistance.
- 6
Verify resistance matches Table 1 temperature/resistance values for ambient temperature.
- 7
If out of range, replace thermistor.
- 8
If in range, inspect and reseat harness linking connector.
- 9
If all checks pass, replace the main controller.
This Error Applies To
LG DLEX7600BE Series Dryers (2017) (2017–present)
Related Error Codes
EEPROM error
Thermistor of blower housing open or shorted
Door switch abnormal
FlowSense - ductwork 90-95% blocked
Thermistor of steam generator open or shorted
Power failure or incorrect power supply
Pump (DC motor) failure
Power supply wire connection wrong or loose (electric dryer only)