LG Dryers2017–present

Error Code tE2

Thermistor of blower housing open or shorted (secondary)

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE2

How to Fix

  1. 1

    Follow identical diagnostic steps as tE1.

  2. 2

    Disconnect power and remove the NA6 connector from the controller.

  3. 3

    Short Pin 4 (Blue Wire) and Pin 3 (Orange Wire) of the NA6 connector with a metal jumper.

  4. 4

    If error clears, check connector seating at NA6 and 6-pin controller connector.

  5. 5

    If error persists, separate the thermistor harness from the thermistor assembly connector and measure resistance.

  6. 6

    Verify resistance matches Table 1 temperature/resistance values for ambient temperature.

  7. 7

    If out of range, replace thermistor.

  8. 8

    If in range, inspect and reseat harness linking connector.

  9. 9

    If all checks pass, replace the main controller.

This Error Applies To

LG DLEX7600BE Series Dryers (2017) (2017–present)

Service manual exact match: DLEX7600WEService manual exact match: DLGX7601BEService manual exact match: DLEX7600BEService manual exact match: DLGX7601VEService manual exact match: DLEX7600VEService manual exact match: DLGX7601WE

Need more help with your LG dryers?