Error Code tE4
Steam generator thermistor open or shorted
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE4
How to Fix
- 1
Enter diagnostic test mode by pressing POWER while pressing MORE TIME and LESS TIME simultaneously.
- 2
Advance through test steps with START/PAUSE until tE4 is triggered.
- 3
Turn power off and discharge voltage.
- 4
Measure resistance between heater terminals 1 and 2 on the steam generator assembly.
- 5
Expected resistance: 14.3Ω ±5%.
- 6
If resistance is out of spec: replace the steam generator assembly.
- 7
If resistance is within spec: check wiring harness between generator and PCB.
- 8
Replace steam generator assembly if thermistor within it tests faulty.
Other Error Codes for DLGX3371R
EEPROM operation is abnormal
Outlet thermistor open or shorted (short circuit variant)
Outlet thermistor open or shorted
Sensors do not detect that steam generator is full within 60 seconds
Electric dryer power cord not connected correctly or house power supply is incorrect
Power failure / house fuse blown / circuit breaker tripped
NFC module is wrong / incompatible
Pump valve resistance less than 10 in test mode; pump circuit fault