Error Code dE
Door is open or door switch fault detected during operation
Moderate
Address soon - your appliance may not work properly
Also displayed as: dE
How to Fix
- 1
Close the dryer door firmly.
- 2
If error persists with door closed: disconnect the WH1 and BL3 connectors from the main PCB.
- 3
Measure resistance between NA6-pin (GN) and chassis ground screw — must be less than 1Ω.
- 4
Disconnect BL2 and WH4 connectors from the main PCB.
- 5
Measure resistance between BL2-(WH) and WH4-(YL): must be less than 1Ω with door closed and open circuit (∞Ω) with door open.
- 6
If these readings are abnormal: check door switch wiring harness for damage.
- 7
If readings are correct but error persists: check door switch COM-NC terminals (1-3) with door open — must be less than 1Ω; COM-NO terminals (1-2) must be open.
- 8
With door closed: COM-NC (1-3) must be open, COM-NO (1-2) must be less than 1Ω.
- 9
Replace door switch if readings are out of spec.
Other Error Codes for DLGX3371W
EEPROM operation is abnormal
Outlet thermistor open or shorted (short circuit variant)
Outlet thermistor open or shorted
Sensors do not detect that steam generator is full within 60 seconds
Electric dryer power cord not connected correctly or house power supply is incorrect
Power failure / house fuse blown / circuit breaker tripped
NFC module is wrong / incompatible
Pump valve resistance less than 10 in test mode; pump circuit fault