Error Code PS
Electric dryer power cord not connected correctly or house power supply is incorrect
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Verify power cord wiring: Neutral (white) to center terminal block screw, Red and Black to left and right terminal block screws, Green ground to external ground screw.
- 2
Check that Black, White, and Red wire connections are correct and not reversed.
- 3
Verify outlet voltage is 208–240VAC ±10% at L1 and L2.
- 4
Check if house fuse is blown or circuit breaker has tripped.
- 5
Reset circuit breaker or replace fuse — do not increase fuse capacity.
- 6
If circuit overload is present: have a qualified electrician correct it.
- 7
Ensure strain relief screw is tightened and all terminal block nuts are tight.
Other Error Codes for DLGX3371W
EEPROM operation is abnormal
Outlet thermistor open or shorted (short circuit variant)
Outlet thermistor open or shorted
Sensors do not detect that steam generator is full within 60 seconds
Power failure / house fuse blown / circuit breaker tripped
NFC module is wrong / incompatible
Pump valve resistance less than 10 in test mode; pump circuit fault
Steam generator thermistor open or shorted