Error Code PS
Power supply wiring error — electric dryer power cord connected incorrectly
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Verify the power cord connection at the terminal block: neutral (white) to center screw, red and black wires to left and right screws.
- 2
For 4-wire connection: connect green ground wire to external ground screw.
- 3
For 3-wire connection: ensure neutral-ground jumper is properly installed if local code permits.
- 4
Confirm strain relief screw is tightened.
- 5
Check house circuit breaker/fuse for 240V supply.
- 6
Measure voltage at outlet: should be 208–240 VAC ±10%.
- 7
If outlet voltage is correct and wiring is confirmed good: re-test. If error persists, check main PCB.
Other Error Codes for DLGX4271W
FlowSense — exhaust duct approximately 95% blocked
NFC module open or shorted
Water supply pump current is less than threshold (pump fault)
FlowSense — exhaust duct approximately 80% blocked
FlowSense — exhaust duct approximately 90% blocked
Humidity sensor failure
NFC module wrong or not recognized
Door open error — door not closed during operation