LG DLGX5781VEDryer
Error Code EE
EEPROM operation abnormal
Moderate
Address soon - your appliance may not work properly
Also displayed as: EE
How to Fix
- 1
Enter diagnostic test mode.
- 2
EE error only appears in test mode.
- 3
If EE is displayed, the EEPROM on the control board is faulty.
- 4
Replace the electronic control assembly (PCB/PWB).
- 5
Observe ESD precautions when handling replacement control board.
Other Error Codes for DLGX5781VE
tE2
Thermistor of blower housing shorted (alternate display for thermistor fault)
dE
Door switch abnormal
E5
Water supply pump failure — pump AD value below 10 in test mode
PS
Power supply wire connection wrong or loose (Black-White-Red wiring)
tE1
Thermistor of blower housing open or shorted
tE4
Steam generator thermistor open or shorted