Error Code HC5

The heat pump compressor has stopped working

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: HC5

What This Means

Compressor repeatedly overheating; Thermistor 5 detecting persistent high temperatures; Restricted airflow in heat pump circuit; Compressor malfunction

What actually causes this:

The compressor that generates heat in a heat pump dryer has shut down, often due to an internal fault.

First Thing to Check

Unplug the dryer for 5 minutes, then plug it back in and try again.

Parts Involved

CompressorThermistor 5

How to Fix

  1. 1

    1. Check compressor operation and condition

  2. 2

    2. Check Thermistor 5 resistance

  3. 3

    3. Inspect heat pump airflow path for obstructions

  4. 4

    4. Clean condenser and evaporator coils

  5. 5

    5. If compressor continues to overheat, replace compressor

Need more help with your Samsung DV22N6850HX?