Error Code dC
The dryer thinks the door is open while running
Moderate
Address soon - your appliance may not work properly
Also displayed as: dC
What This Means
Door not fully closed or latched; Laundry caught in the door preventing proper closure; Door switch malfunction; Loose wire terminals in door sense circuit
What actually causes this:
Door wasn't closed firmly, or the door switch has gone bad from normal wear.
First Thing to Check
Open and firmly close the door, then try starting it again.
Parts Involved
How to Fix
- 1
1. Make sure the door is properly closed
- 2
2. Check that laundry is not caught in the door
- 3
3. Test door switch with door OPEN: COM-NC (pins 1-3) should read < 1Ω, COM-NO (pins 1-2) should read ∞
- 4
4. Test door switch with door CLOSED: COM-NC (pins 1-3) should read ∞, COM-NO (pins 1-2) should read < 1Ω
- 5
5. If door switch fails test, replace door switch
Other Error Codes for DVG50M7450W
A secondary temperature sensor is giving bad readings
The dryer's internal parts aren't communicating properly
Your dryer's temperature sensor isn't reading correctly
Your dryer is getting the wrong type of electrical power
Your dryer is getting the wrong voltage from the outlet
The door switch isn't working properly
Your dryer isn't heating properly or is overheating