LG Dishwashers2017–present

Error Code FE

Excess Error — water fills above normal level; drain pump auto-activates

Moderate

Address soon - your appliance may not work properly

Also displayed as: FE

What This Means

Inlet valve stuck open or leaking; Hall sensor (flow meter) faulty; Main PCB fault

How to Fix

  1. 1

    Step 1: Measure inlet valve resistance — should be 23-27Ω. If shorted or out of spec, replace inlet valve.

  2. 2

    Step 2: Measure voltage at WH6 pin5~pin6 — should be 8V DC ±15%. If out of range, replace main PCB.

  3. 3

    Step 3: Measure hall sensor resistance at NA8/WH4 — should be 9kΩ ±5%. If out of spec, replace hall sensor.

  4. 4

    Step 4: Measure hall sensor control voltage — should be 5V DC ±15%. If absent, replace main PCB assembly.

  5. 5

    Step 5: If PCB was replaced and FE error persists, replace hall sensor.

This Error Applies To

LG LDF5545SS Series Dishwashers (2017) (2017–present)

Service manual exact match: LDF5545STService manual exact match: LDF5545BBService manual exact match: LDF5545WWService manual exact match: LDT5665SSService manual exact match: LDT5665STService manual exact match: LDT5665BBService manual exact match: LDT5665WWService manual exact match: LDB4548SS+2 more