Error Code E5
Steam pump error — pump AD value below threshold during diagnostic test
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
How to Fix
- 1
Enter diagnostic test mode: press Power then immediately Temp and Time.
- 2
Press START/PAUSE four times to reach the pump check step.
- 3
Observe the pump AD value on the display — value must be greater than 10 for pump to be considered normal.
- 4
If value is 10 or below, E5 is displayed indicating pump failure.
- 5
Disconnect power and inspect the steam pump wiring harness for loose connectors or damaged wires.
- 6
Check pump coil resistance — rated 24 Ω ±10% (same as inlet valve); limit current 550 mA.
- 7
Inspect the inlet hose connection to the pump/generator for kinks or blockage.
- 8
Replace the steam pump if resistance is out of range or pump does not respond.
- 9
After replacement, re-enter diagnostic mode and confirm AD value exceeds 10.
This Error Applies To
LG DLE8400BE Series Dryers (2023) (2023–present)
Related Error Codes
Power supply error — electric dryer power cord not connected correctly or house power supply incorrect; also displayed when 240V is applied to PCB indicating mis-wired power cord
Duct blockage — ductwork approximately 90% blocked (displayed for 2 hours only)
Temperature sensor (thermistor) failure — open circuit
Power failure — house fuse blown, circuit breaker tripped, or power outage
Duct blockage — ductwork approximately 95% blocked (displayed for 2 hours only)
Temperature sensor (thermistor) failure — shorted circuit
No power / power code error — outlet voltage issue or power cord not properly connected
Flow Sense duct blockage restriction detected after drying cycle ends