LG Dryers2023–present

Error Code GAS

Gas supply error — gas not supplied to the dryer

Moderate

Address soon - your appliance may not work properly

Also displayed as: GAS

How to Fix

  1. 1

    Confirm the house gas shutoff valve is fully open.

  2. 2

    Confirm the dryer gas shutoff valve (within 6 ft of dryer) is fully open.

  3. 3

    Inspect the gas supply line for proper connection at the dryer's 3/8-inch NPT connection.

  4. 4

    Check for gas leaks using a non-corrosive leak detection fluid on all pipe connections.

  5. 5

    If gas is confirmed flowing but GAS error persists, enter diagnostic mode and check Valve 1 voltage — should be 90 Vdc or higher when igniting.

  6. 6

    If valve voltage is present, test gas valve resistance: Valve 1 and Valve 2 each should read 1.5 kΩ–2.5 kΩ; replace valve if out of range.

  7. 7

    Check igniter resistance (part 5318EL3001): should be 50–800 Ω.

  8. 8

    Check flame detector: open above 370°F, closed below 320°F with resistance less than 1 Ω when closed.

  9. 9

    If all components test good and error persists, replace the main PCB.

This Error Applies To

LG DLE8400BE Series Dryers (2023) (2023–present)

Service manual exact match: DLG8401WEService manual exact match: DLE8400BEService manual exact match: DLE8400WEService manual exact match: DLG8401BE