Error Code tE2
Outlet thermistor open or shorted (short circuit variant)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Follow the same diagnostic procedure as tE1.
- 2
tE2 typically indicates a shorted thermistor rather than open circuit.
- 3
Turn power off and discharge voltage.
- 4
Disconnect the NA6 connector from the main PCB.
- 5
Measure resistance between thermistor terminals.
- 6
If resistance is near 0Ω (shorted): replace the thermistor.
- 7
If resistance is within Table 1 range: check harness connectors for pinched or shorted wires.
- 8
If harness is good: replace the main PCB controller.
This Error Applies To
LG DLEX3570V Series Dryers
Related Error Codes
No power / power supply fault
EEPROM operation is abnormal
Pump valve resistance less than 10 in test mode; pump circuit fault
Outlet thermistor open or shorted
Sensors do not detect that steam generator is full within 60 seconds
Electric dryer power cord not connected correctly or house power supply is incorrect
NFC module open or shorted
Steam generator thermistor open or shorted