Error Code PS
Power supply wire connection wrong or loose (electric dryer)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Verify power cord wiring: Black wire to L1, White wire to Neutral (center), Red wire to L2.
- 2
Check that all terminal block nuts are tight and power cord is in correct position.
- 3
Check voltage at outlet: should be 208–240VAC between L1 and L2.
- 4
Reset circuit breaker or replace fuse if blown; do not increase fuse capacity.
- 5
If power supply is correct, check for loose or crossed connections at terminal block.
- 6
Refer to Section 3-1 Connecting Electric Dryers for complete wiring instructions.
- 7
If connections are correct and error persists, replace the main PCB.
This Error Applies To
LG DLEX4370V Series Dryers
Related Error Codes
Outlet thermistor open or shorted (second thermistor)
NFC module open or shorted
Ductwork approximately 80% blocked
Steam generator thermistor open or shorted
Power failure or incorrect power supply
NFC module wrong or unresponsive
Ductwork approximately 90% blocked
Outlet thermistor open or shorted