LG Dryers2014–present

Error Code PS

Power supply wire connection wrong or loose (Black-White-Red wiring)

Moderate

Address soon - your appliance may not work properly

Also displayed as: PS

How to Fix

  1. 1

    Verify outlet voltage is 110–125V AC.

  2. 2

    If no outlet voltage, check fuse or circuit breaker.

  3. 3

    With dryer powered on, verify voltage between connector BK2 or WH2-1 (Black Wire) and BL2-3 (White wire) to controller.

  4. 4

    If voltage is absent, check that power cord is properly connected.

  5. 5

    Check if controller wire is disconnected; reconnect controller if needed.

  6. 6

    Check terminal block and power cord connection; verify N (neutral) line matches terminal center N.

  7. 7

    If wiring checks pass, replace controller.

  8. 8

    Refer to wiring diagram pages 7–9 for wire connection guidance.

  9. 9

    Verify Black-White-Red wire order matches wiring diagram.

  10. 10

    This code applies to electric dryer only.

This Error Applies To

LG DLEX5780VE Series Dryers (2014) (2014–present)

Service manual exact match: DLGX5781WEService manual exact match: DLEX5780VEService manual exact match: DLEX5780WEService manual exact match: DLGX5781VE