Error Code tE2
Thermistor fault — blower housing thermistor open or shorted (alternate code)
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE2
How to Fix
- 1
Follow the same diagnostic procedure as tE1.
- 2
Turn power off and discharge capacitors.
- 3
Remove connector NA6 and short Pin 2 (Blue Wire) and Pin 5 (Orange Wire) to the controller.
- 4
If error clears, verify harness connections and replace controller if needed.
- 5
If error persists, measure thermistor resistance and compare to Table 1 values.
- 6
Replace thermistor if out of range; inspect harness connector if in range.
This Error Applies To
LG DLEX7900VE Series Dryers
Related Error Codes
Steam generator thermistor open or shorted
Humidity sensor failure
Steam pump AD value below 10 — pump abnormal
EEPROM error — EEPROM operation is abnormal
FlowSense four-bar restriction detected — ductwork significantly restricted
Door switch abnormal — detected only in TEST MODE
Ductwork approximately 90% blocked — FlowSense alert
Thermistor fault — blower housing thermistor open or shorted