Error Code LE1
Restricted motor — motor fails to start after restart attempts
Moderate
Address soon - your appliance may not work properly
Also displayed as: LE1
How to Fix
- 1
Check for physical/structural restriction: inspect motor supporter and air guide blower for obstructions or interference
- 2
Check motor wiring connector at main PCB (white 10-pin housing, orange/white/yellow wires) — verify connector is fully seated
- 3
Measure BLDC motor winding resistance (refer to component testing page 34): U/V, V/W, W/U each should be 20 Ω ±2 at 25°C
- 4
If motor windings are out of spec, replace BLDC motor (R code: C200)
- 5
If wiring and motor are good, replace main PCB (R code: A160)
This Error Applies To
LG DLHC1455 Series Dryers (2020) (2020–present)
Related Error Codes
Wi-Fi module communication error — Wi-Fi module single product fault
Wi-Fi product not registered (normal behavior until registered) or Wi-Fi module error
Compressor discharge pipe thermistor open or short circuit
Drum outlet thermistor open or short circuit
Compressor error — inverter compressor fault after restart attempts
Power cord incorrectly connected or power supply error (not 240V — may be 120V only)
Drum outlet thermistor open or short circuit
Door open detected during operation — machine restarts then stops