Error Code LE2
Low electric current detected — compressor operation repeats 3 times then stops
Moderate
Address soon - your appliance may not work properly
Also displayed as: LE2
How to Fix
- 1
Check and clean the double lint filter — clogged filter restricts airflow and can cause low compressor load
- 2
Check ambient temperature around the appliance — must be above 45°F (7°C); extremely low ambient can cause this fault
- 3
Check compressor harness connections (blue, red, black wires) at inverter connector on main PCB
- 4
In LQC test mode (press More Time + Less Time + Power), press start button 3 times to activate compressor test; measure current on blue, red, and black harness wires — normal is >0.2A; refrigerant leak suspected if <0.1A
- 5
If refrigerant leak is confirmed (check for oil residue around compressor and evaporator), replace base assembly (R code: C600)
- 6
If compressor and refrigerant are OK, replace main PCB (R code: A160)
This Error Applies To
LG DLHC1455 Series Dryers (2020) (2020–present)
Related Error Codes
Restricted motor — motor fails to start after restart attempts
Wi-Fi module communication error — Wi-Fi module single product fault
Wi-Fi product not registered (normal behavior until registered) or Wi-Fi module error
Compressor discharge pipe thermistor open or short circuit
Drum outlet thermistor open or short circuit
Compressor error — inverter compressor fault after restart attempts
Power cord incorrectly connected or power supply error (not 240V — may be 120V only)
Drum outlet thermistor open or short circuit