Error Code OE
Drainage pump failure — water not draining properly
Moderate
Address soon - your appliance may not work properly
Also displayed as: OE
How to Fix
- 1
Check that drain hose is not twisted, kinked, or blocked
- 2
Check pump connector at main PCB — verify it is fully seated and not damaged
- 3
Check water level (sump) sensor connector — verify it is fully seated
- 4
Check hose connected to pump for blockage or clogging
- 5
In LQC test mode, press start button twice to activate pump test; pour water into dispenser hose until sump water level shows '1'; verify pump operates
- 6
Disassemble pump cover assembly (pages 65-66): remove foreign matter, check impeller for restriction; if pump is damaged, replace pump (R code: C251)
- 7
If pump and hoses are all clear, replace main PCB (R code: A160)
This Error Applies To
LG DLHC1455 Series Dryers (2020) (2020–present)
Related Error Codes
Restricted motor — motor fails to start after restart attempts
Wi-Fi module communication error — Wi-Fi module single product fault
Wi-Fi product not registered (normal behavior until registered) or Wi-Fi module error
Compressor discharge pipe thermistor open or short circuit
Drum outlet thermistor open or short circuit
Compressor error — inverter compressor fault after restart attempts
Power cord incorrectly connected or power supply error (not 240V — may be 120V only)
Drum outlet thermistor open or short circuit