Error Code E CF
Condenser Fan Error / BLDC Fan Motor Abnormality for Mechanic Room
Moderate
Address soon - your appliance may not work properly
What This Means
Condenser fan motor seized or obstructed; BLDC feedback signal absent for more than 65 seconds; Loose connection at CON5; Defective fan motor drive IC or transistor
How to Fix
- 1
Reset the unit and enter Test 1 Mode by pressing test button 1 time
- 2
Check condenser fan rotating in machine compartment
- 3
Note: while error code is displayed the fan is not working
- 4
If fan not rotating: manually rotate fan by hand — if sticky, replace motor
- 5
Check for loose connection at CON5
- 6
Check condenser motor voltage at CON5: 4th pin to 6th pin should be above 10V; if below 10V, replace PCB
- 7
Check CON5 1st pin to 3rd pin: expect 0 or 5V; if not, replace PCB
- 8
Check CON5 6th pin to 4th pin: expect 0 or 5V; if not, replace condenser fan motor
This Error Applies To
LG LF21G6200S Series Refrigerators (2023) (2023–present)