Error Code E dH
Defrost Heater Error / Freezer Defrosting Error
Moderate
Address soon - your appliance may not work properly
What This Means
Defrost heater open circuit; Fuse-M blown; Defrost sensor out of range; Main PCB relay failed; 80 minutes elapsed since defrost start without defrost sensor reaching 41F/5C
How to Fix
- 1
Push test button 1 time to enter Test 1 Mode
- 2
Check door gasket for proper seal
- 3
Check for loose connection at defrost control part connector
- 4
Check resistance of defrost control parts: Fuse-M should read 0 Ohm; if other reading, replace Fuse-M
- 5
Check defrost heater resistance: expect 34-42 Ohm; if out of range, replace heater
- 6
Check defrost sensor resistance against temperature table; if out of range, replace sensor
- 7
Enter Test 3 Mode by pressing test button 3 times (forces defrost mode, display shows 33 33)
- 8
Check for loose connection at CON8
- 9
Check voltage between Brown and RED wires at CON8: expect 112-116V AC; if 0V, replace Main PCB
- 10
If voltage is present but heater does not heat, replace defrost heater assembly
- 11
Release test mode after diagnosis
This Error Applies To
LG LF21G6200S Series Refrigerators (2023) (2023–present)