Error Code E CO
Communication Error between Main PCB MICOM and Display MICOM
Moderate
Address soon - your appliance may not work properly
What This Means
Loose connection at CON101 on display PCB; Poor communication line connection; Defective transmitter or receiver transistor between display and main board; Defective display PCB; Defective main PCB
How to Fix
- 1
Check for loose connection at CON101 on display PCB
- 2
Check voltage between BO/WH and PK/BL wires at CON101: if 5V, go to next step; if other, check hinge connection — if still other, replace Main PCB
- 3
Check voltage between PK/BL and PR/WH wires at CON101: if 0V or 5V, replace Display PCB; if other, continue
- 4
Check voltage between PK/BL and ground at CON5: if 0V or 5V, replace Main PCB; if other, continue
- 5
Check for loose connection at CON5 on main PCB
- 6
Check voltage between PR/BL and PK/BL: if 0V or 5V, replace Display PCB; if other, continue
- 7
Check voltage between RD/YL and PK/BL: if 0V or 5V, replace Main PCB; if other, explain to customer
This Error Applies To
LG LF21G6200S Series Refrigerators (2023) (2023–present)