Error Code E CH
High Side Cycle Leakage (Refrigerant Leak or Sealed System Problem)
Moderate
Address soon - your appliance may not work properly
What This Means
High-side refrigerant leak (condenser, drier, high-pressure tubing); Partial or complete restriction in high-side sealed system; Compressor not pumping adequately; Bad expansion valve
How to Fix
- 1
Use LG SVC App jig if available to determine if issue is compressor or sealed system; if no jig, use temperature gun to check condenser temperature
- 2
Check voltage to determine if it is a PCB problem
- 3
Measure high-pressure side (drier) and low-pressure side (compressor processing pipe) pressure
- 4
Check equalization return time after stopping compressor: if clogging is present, equalization takes more than 15 minutes
- 5
Check equalized pressure to determine if sufficient refrigerant is present
- 6
If refrigerant is low, perform leak test using refrigerant or nitrogen gas
- 7
Check high-pressure parts for leaks: condenser, drier, associated tubing
- 8
If no high-pressure leaks, check low-pressure parts: evaporator, suction pipe
- 9
After sealed system repair, error code clears automatically when freezer temperature drops to 14F or below
- 10
On follow-up visit, check for leaks using UV dye in drier
This Error Applies To
LG LF21G6200S Series Refrigerators (2023) (2023–present)