Error Code E CL
Low Side Cycle Leakage (Refrigerant Leak or Sealed System Problem)
Moderate
Address soon - your appliance may not work properly
What This Means
Low-side refrigerant leak (evaporator, suction pipe); Partial or complete restriction in low-side sealed system; Compressor fault; Extended door-open time causing apparent low-side issue
How to Fix
- 1
Use LG SVC App jig if available to determine if issue is compressor or sealed system; if no jig, use temperature gun
- 2
Check voltage to determine if it is a PCB problem
- 3
Measure high-pressure side (drier) and low-pressure side (compressor processing pipe) pressure
- 4
Check equalization return time: if clogging, equalization takes more than 15 minutes
- 5
Check equalized pressure to confirm sufficient refrigerant and diagnose compressor vs. leak
- 6
If refrigerant is low, perform leak test using refrigerant or nitrogen gas
- 7
Check low-pressure parts for leaks: evaporator, suction pipe
- 8
If no low-pressure leaks, check high-pressure parts: condenser, drier
- 9
After sealed system repair, error code clears automatically when freezer temperature drops to 14F or below
- 10
On follow-up visit, check for leaks using UV dye in drier
This Error Applies To
LG LF21G6200S Series Refrigerators (2023) (2023–present)