LG Refrigerators2023–present

Error Code E CO

Communication Error between Main PCB MICOM and Display MICOM

Moderate

Address soon - your appliance may not work properly

What This Means

Loose connection at CON101 on display PCB; Poor communication line connection; Defective transmitter or receiver transistor between display and main board; Defective display PCB; Defective main PCB

How to Fix

  1. 1

    Check for loose connection at CON101 on display PCB

  2. 2

    Check voltage between BO/WH and PK/BL wires at CON101: if 5V, go to next step; if other, check hinge connection — if still other, replace Main PCB

  3. 3

    Check voltage between PK/BL and PR/WH wires at CON101: if 0V or 5V, replace Display PCB; if other, continue

  4. 4

    Check voltage between PK/BL and ground at CON5: if 0V or 5V, replace Main PCB; if other, continue

  5. 5

    Check for loose connection at CON5 on main PCB

  6. 6

    Check voltage between PR/BL and PK/BL: if 0V or 5V, replace Display PCB; if other, continue

  7. 7

    Check voltage between RD/YL and PK/BL: if 0V or 5V, replace Main PCB; if other, explain to customer

This Error Applies To

LG LF21G6200S Series Refrigerators (2023) (2023–present)

Service manual exact match: LF21G6200S/00Service manual exact match: LF21G6200S

Need more help with your LG refrigerators?