Error Code E CO
Communication Error — Main MICOM to Display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check connector CON101 for loose or disconnected wiring. Check hinge harness routing for pinching or damage. Reconnect any loose connections.
- 2
Measure voltage at CON101 1st Pin to 2nd Pin. Expected: 12 V. If voltage is not 12 V, check hinge connection or replace main PCB.
- 3
Measure voltage at CON101 5th Pin to 2nd Pin. Expected: 12 V. If voltage is not 12 V, check hinge connection or replace main PCB.
- 4
Measure voltage at CON101 3rd Pin to 2nd Pin. Expected: not 0 or 5 V (oscillating data signal). If voltage is 0 or 5 (static), replace display PCB.
- 5
Measure voltage at CON101 4th Pin to 2nd Pin. Expected: not 0 or 5 V. If static, replace main PCB.
- 6
Measure voltage at CON5 4th Pin to 3rd Pin. Expected: not 0 or 5 V. If static, replace display PCB.
- 7
Measure voltage at CON5 5th Pin to 3rd Pin. Expected: not 0 or 5 V. If static, replace main PCB.
- 8
If all voltage checks pass, explain normal operation to customer.
This Error Applies To
LG LF29H8330D Series Refrigerators