Defect of BLDC fan motor for freezer
Moderate
Address soon - your appliance may not work properly
Also displayed as: E FF
How to Fix
- 1
Power cycle the unit and enter Test Mode 1 (press TEST button once on Main PCB).
- 2
Open the freezer door and check for airflow from the fan; if airflow is present and windy, go to step 5.
- 3
If no airflow, manually rotate the fan blade by hand. If the fan feels sticky or seized, replace the fan motor.
- 4
If fan rotates freely, measure motor supply voltage at CON4 20th Pin to 19th Pin in Test Mode 1; expected 11.4 to 12.6V.
- 5
If motor supply voltage is not present (not 11.4–12.6V), replace the Main PCB.
- 6
If supply voltage is correct, measure fan feedback voltage at CON4 18th Pin to 19th Pin; expected signal (not 0 or 5V fixed).
- 7
If feedback voltage is 0V or 5V (fixed), replace the freezer fan motor.
- 8
If feedback is correct, measure PWM voltage at CON4 17th Pin to 19th Pin; expected not fixed 0 or 5V.
- 9
If PWM voltage is fixed 0V or 5V, replace the Main PCB.
- 10
If all voltages are correct, explain normal operation to customer.
This Error Applies To
LG LF29S8330 Series Refrigerators
Related Error Codes
Defect of room temperature (RT) sensor
Defect of humidity sensor
Defect of freezer sensor
Defect of refrigerator sensor
Defect of ice-room sensor or ice maker sensor
Defect of freezer defrosting sensor
Convertible room sensor error (pantry sensor error)
Defect of ice maker kit