Error Code E gF

Defect of flow meter

Moderate

Address soon - your appliance may not work properly

Also displayed as: E gF

How to Fix

  1. 1

    Check that the saddle valve or household water supply shutoff is fully open.

  2. 2

    Check the flow meter connector at the Main PCB; reconnect if loose.

  3. 3

    With power OFF, measure flow sensor resistance between the Red wire and Black wire; expected range 4 to 30 kOhm.

  4. 4

    If resistance is outside this range, replace the flow sensor.

  5. 5

    Verify water filter is not clogged or past replacement interval (replace every 6 months).

  6. 6

    Check all water valve housing connections for proper seating.

  7. 7

    If connections and sensor check OK, replace the Main PCB.

This Error Applies To

LG LF29S8330 Series Refrigerators

Service manual exact match: LF29S8330SService manual exact match: LF29S8330BService manual exact match: LF29S8330WService manual exact match: LF29S8330D