Error Code E Sd
Sub PCB communication error
Moderate
Address soon - your appliance may not work properly
Also displayed as: E Sd
How to Fix
- 1
Check loose connections between main PCB and Sub PCB harness; reconnect if loose.
- 2
Measure voltage at CON1 (Sub) 8th Pin to 33rd Pin; expected active signal (not fixed 0 or 5V). If fixed 0 or 5V, check Sub PCB connection; if connection is normal, replace Sub PCB.
- 3
Measure voltage at CON1 (Sub) 10th Pin to 33rd Pin; expected active signal (not fixed 0 or 5V). If fixed, check Sub PCB connection; if normal, replace Sub PCB.
- 4
Measure voltage at CON3 (Main) 1st Pin to 15th Pin; expected active signal (not fixed 0 or 5V). If fixed, check Display PCB connection; if normal, replace Display PCB.
- 5
Measure voltage at CON3 (Main) 3rd Pin to 15th Pin; expected active signal (not fixed 0 or 5V). If fixed, check Display PCB connection; if normal, replace Display PCB.
- 6
If all checks pass, explain normal operation to customer.
This Error Applies To
LG LF29S8330 Series Refrigerators
Related Error Codes
Defect of humidity sensor
Defect of room temperature (RT) sensor
Defect of freezer sensor
Defect of refrigerator sensor
Defect of ice-room sensor or ice maker sensor
Defect of freezer defrosting sensor
Convertible room sensor error (pantry sensor error)
Defect of ice maker kit