Error Code CO E
Communication Error
Moderate
Address soon - your appliance may not work properly
Also displayed as: CO E
How to Fix
- 1
Check all connectors for loose connections throughout the wiring harness.
- 2
Measure voltage at CON101 pin 7 to pin 6. Expected: 12V. Also measure CON101 pin 3 to pin 6. Expected: 5V. If voltages are incorrect: check hinge connector for loose connection; if hinge connection is good and voltages still wrong: replace Main PCB.
- 3
Measure CON101 pin 5 to pin 6. Expected: 0V or 5V (toggling). If not 0V or 5V: replace the Display PCB.
- 4
Measure CON101 pin 4 to pin 6. Expected: 0V or 5V. If not 0V or 5V: replace Main PCB.
- 5
Measure CON6 pin 8 to pin 9. Expected: 0V or 5V. If not 0V or 5V: replace Display PCB.
- 6
Measure CON6 pin 10 to pin 9. Expected: 0V or 5V. If not 0V or 5V: replace Main PCB.
This Error Applies To
LG LFXS26973 Series Refrigerators