Error Code CH E
High-Side Cycle Leakage / Sealed System Problem
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
1. Use LG SVC App Step 1 to determine if issue is compressor or sealed system. If no SVC App, use temperature gun to measure condenser outlet temperature.
- 2
2. Check voltage at PCB to rule out PCB problem.
- 3
3. Check high/low side pressures and equalization return time using SVC App Step 2 or manifold gauge set.
- 4
4. If equalization time exceeds 15 minutes, sealed system is blocked.
- 5
5. If equalization pressure is below 40 psi, likely a refrigerant leak.
- 6
6. Charge with N2 or R134a (per local code) to locate leak.
- 7
7. Check high-pressure side parts (condenser, drier) for leaks using leak detector.
- 8
8. If no high-side leak found, check low-pressure side parts (evaporator, suction pipe).
- 9
9. Replace all leaking parts along with the drier.
- 10
10. If compressor is determined faulty, replace compressor and drier.
- 11
11. After sealed system repair, error clears automatically when freezer reaches 14°F.
- 12
12. Use UV drier for leak verification on next visit.
- 13
13. If system is normal but error persists, press F key + R key 3 times with door open to force-clear error code.
This Error Applies To
LG LHFS28XBS Series Refrigerators